The requirement
Measured on the walking line, a winder’s going must be at least 240 mm (210 mm on a spiral). You can use up to 3 winders for a quarter turn, or 6 for a half turn, in place of a landing. A landing must be at least 750 mm long (NCC 2025, Housing Provisions Part 11.2).
Turning a stair is where a lot of good work goes wrong. You’ve got two ways to do it. A landing is a flat platform you step onto mid-flight. Winders are the pie-shaped turning treads that fan around a corner. Part 11.2 sets out how to do both safely.
Winders and the walking line. A winder is a tapered tread. It’s wide on the outside of the turn and pinched to almost nothing on the inside. Its going (the depth you actually step onto) changes as you move across it. So the code measures it on a walking line, the path a person’s feet really take round the bend. Where that line sits depends on the stair:
| Stair type | Where the walking line sits |
|---|---|
| 1 m wide or less | Down the middle |
| Wider than 1 m | 400 mm in from each side |
| Spiral / circular | 0.7 of the width out from the centre pole |
The going you measure on that line is the one that has to pass. It must meet Table 11.2.2a:
| What | Minimum | Maximum |
|---|---|---|
| Going (standard) | 240 mm | 355 mm |
| Going (spiral) | 210 mm | 370 mm |
| Riser (standard) | 115 mm | 190 mm |
| Riser (spiral) | 140 mm | 220 mm |
Using winders instead of a landing? Then every winder must have the same going, a constant step round the whole turn. You can’t have a couple of generous ones and then a tight one that catches a heel.
- 1 walking line
- 2 winder tread
- 3 landing
Where winders are allowed. Only in place of a landing, at a turn. Never part-way along a straight flight. Up to 3 winders make a quarter turn (90 degrees). Up to 6 winders make a half turn (180 degrees). Any more than that and you need a landing instead.
Landings. A flight can have at most 18 risers and at least 2. That cap is what forces a landing into a long run. You can’t just keep stacking steps forever. The landing rules (clause 11.2.5):
- At least 750 mm long.
- On a turn, measure that 750 mm at a line 500 mm in from the inside edge. That’s the tight side of the corner. It stops the short side cheating the length.
- No steeper than 1:50.
- Must run the full width of any doorway that opens onto it.
- You need a landing where a doorway opens onto a stair with a drop of more than 3 risers or 570 mm. That way nobody steps straight out of a door into a fall.
Work it out by hand
You’re framing a quarter turn at the bottom of a stair. You want 3 winders instead of a landing. The stair is 900 mm wide, under a metre. So the walking line runs down the middle.
- Find the walking line. 900 mm wide, so the line sits at 450 mm, the centre of the tread.
- Set the going on that line. Your treads must give at least 240 mm of going on that middle line. Say you set them out so the walking line reads 250 mm. That clears the 240 mm minimum with a touch of room to spare. It also sits well under the 355 mm maximum. (250 mm is just an example set-out, not a code figure. The code figure is the 240 mm minimum.)
- Keep them equal. These winders replace a landing, so all three must have the same going on the walking line. Mark and cut them off one story pole so they match.
- Check the count. 3 winders for a 90-degree turn. That’s the limit, so you’re fine. Needed a full 180? You’d be allowed up to 6.
So: 3 equal winders, walking line down the middle, at least 240 mm of going on that line. That’s a legal quarter turn.
Do it in 5 seconds
Related
- Part of the NCC rules for Australian chippies — the pillar guide, with the state-by-state adoption tracker.
- Getting the straight runs right first? See NCC stair requirements: riser, going & the 2R+G rule.
- Fitting the barrier round the turn? See Balustrade height requirements: when do you need one?.
Sources
- NCC 2025, ABCB Housing Provisions Standard, Part 11.2 (Stairway and ramp construction) — winder goings and the walking line (cl 11.2.2), Table 11.2.2a goings and risers, the 18/2 riser limits, and landings (cl 11.2.5). Confirm the 240 mm / 355 mm goings, the 115–190 mm risers, the 750 mm landing length, and the 3-winder quarter-turn / 6-winder half-turn rule at ncc.abcb.gov.au. (Confirmed against the NCC 2025 Housing Provisions Standard, verified 2026-07-28.)
Related building rules
More Australia rules