Quick reference: key numbers & code scope
| Requirement / item | Governing figure / rule |
|---|---|
| Code edition / standard | Accessibility arrêtés (1 Aug 2006 & 24 Dec 2015) — scope-limited, exempt for a self-build |
| Governing clause(s) | FR CCH L161-1, FR Arrêté 2015-12-24, FR Arrêté 2006-08-01 |
| Maximum gradient | no fixed rule |
Check the scope first
CCH L161-1 gives an access-rule exemption for owners who build or improve a home for their own use. Other safety rules still apply. Check the scope for a home built for sale or rent. Public buildings use other texts.
Article 2 of the 24 December 2015 order covers the outside access route for housing within its scope. It sets these slopes:
- At most 5% in the normal case.
- Up to 8% for at most 2 m in an exceptional case.
- Up to 10% for at most 0.50 m in an exceptional case.
- Rest landings at both ends. Add one every 10 m if the slope is 4% or more.
Do not use the terrace exception for any ramp
Article 14 covers balconies, terraces and loggias. In specified cases, space must be left to add a ramp later. The text uses 10% over 2 m and 12% over 0.50 m for that space. It also has a 12% case for a terrace without the stated insulated screed.
These are not general limits for ramps inside a home. Read Article 14 for the full scope, threshold and clear space rules.
Work out the run
A 300 mm rise at 5% needs 300 ÷ 0.05 = 6000 mm of flat run. Add the level areas at the ends. A shorter run does not mean you can just use a steeper slope.
Sources
Scope and figures checked on 6 September 2026. Confirm the rules for the actual building and work before setting out.
Related building rules
More France rules
Ramps in other countries
- House Ramp Gradients: Choose the Right NCC Path
- US Ramp Slopes (IRC R311.8)
- NZ Ramp Gradients (NZBC D1)
- UK Ramp Gradients (Approved Document M)
- Canada Ramp Slopes (NBC 9.8)
- Irish Dwelling Ramp Gradients: TGD M Rules
- German Ramp Gradients: DIN 18040-2 Slope Rules
- Spanish Ramp Gradients: CTE DB-SUA Slope Rules
- Indonesian Ramp Gradients: Indoor, Outdoor & Landings
- Japanese Ramp Gradients: Slope, Landings & Width
- Indian Ramp Guidance: NBC 2016 Scope and Gradients
- Norwegian Ramp Gradients: TEK17 §12-16
- Swedish Ramp Gradients: 1:12 Accessible Limit