The requirement
For a private stair, each rise can be at most 220 mm, each going at least 220 mm (TGD K 2014, Table 1). The optimum is a 175 mm rise on a 250 mm going. The maximum pitch is 42°, with 35° the optimum (par. 1.1.4).
Two words to know. The rise is how tall each step is. The going is how deep it is, the flat part you stand on. These numbers come from TGD Part K, the Technical Guidance Document for Stairways, Ladders, Ramps and Guards. Its 2014 edition is the deemed-to-satisfy route under the Irish Building Regulations. Keep every step in a flight the same, so the stair climbs evenly.
A stair also has to pass the 2R+G check. That means twice the rise plus the going. Table 1, Note 4 sets it between 550 mm and 700 mm, with 600 mm the optimum. It is a quick way to spot a stair that is too steep or too shallow before you cut a stringer.
Two more numbers finish it off:
- Headroom. At least 2000 mm clear above the stair (par. 1.1.9, Diagram 3). In a loft conversion that can drop to 1900 mm at the centre line of the stair. A minor side projection can come down to 1800 mm.
- Width. A private stair needs a clear width of at least 800 mm (par. 1.1.10). A flight also cannot run more than 16 risers without a landing (par. 1.1.11).
Guards & barriers
The handrail sits 900–1000 mm above the pitch line on a flight, and 900–1100 mm above a landing (par. 1.1.17). Fit it to one side if the stair is 1000 mm wide or less. Fit it to both sides if the stair is wider.
Guarding protects any edge a person could fall from. In a single-family dwelling, TGD K’s Diagram 6 (par. 1.1.20) sets the guard heights.
| Where | Guard height |
|---|---|
| Stair, ramp or landing | 900 mm |
| Floor, balcony or roof edge | 1100 mm |
The gaps in the guarding matter too. A small child must not fit through.
- A 100 mm sphere must not pass through any opening in the guarding.
- The guarding must not be readily climbable.
- A cut-string stair has an open triangle under each tread, between the tread, the riser and the string. That gap is not allowed in a dwelling (par. 1.1.19).
Work it out on site
Say your floor-to-floor height is 2800 mm and you are setting out a private stair.
- Pick how many risers. 2800 ÷ 220 = 12.7, and 220 mm is the tallest a rise can be. You cannot have part of a step, so round up to 13 risers. 2800 ÷ 13 = 215 mm per rise. That is under the 220 mm limit. It also sits well inside the 16-riser limit for a single flight.
- Set the going. Try 220 mm, the minimum. Thirteen risers means 12 goings. So the stair runs 12 × 220 = 2640 mm along the floor. Check that fits the space.
- Check 2R+G. 2 × 215 + 220 = 650 mm. That sits inside the 550–700 mm band, so the pitch is comfortable.
The calculator does this rounding and the 2R+G check for you. It keeps every rise even too.
Do it in 5 seconds
Related
- Irish Building Regulations hub — how the one national rule book and its TGDs work.
- UK stair and barrier requirements — the Approved Document K numbers, for anyone comparing across the Irish Sea.
Sources
- TGD Part K (2014) — Stairways, Ladders, Ramps and Guards, Table 1 (rise, going, pitch and 2R+G), par. 1.1.9 / Diagram 3 (headroom), par. 1.1.10–1.1.11 (width and risers per flight), par. 1.1.17 (handrail height) and par. 1.1.19–1.1.20 / Diagram 6 (guarding). Read it at gov.ie.
Read this first. The figures above are from the 2014 edition of TGD Part K, in force since 1 January 2015 — this is the deemed-to-satisfy route, not the only legal one. A superseded 1997/2005 edition of TGD K still circulates online and gives different numbers: a handrail of 840–900 mm and a private-stair guard of 840 mm. TGDs also carry transitional arrangements, so the edition in force can vary by the commencement or permission date of your job. Always confirm you’re reading the current edition on gov.ie before you build to it.
Related building rules